5kw 2500rpm High Power Density Permanent Magnetic AC Motor

5kw 2500rpm High Power Density Permanent Magnetic AC Motor

5KW 2500RPM Large Electrical power Density Long lasting Magnetic AC Motor

Product Feature
one.Suited for the 2500rpm rated pace
two.Higher electricity & large torque
3.Substantial effectiveness
4.Modest size
5.Reduced sounds lower vibration
6.Patented cooling construction
7.Effortless upkeep and long daily life time
8.Durable, trustworthy

Specifications
Model variety: SRPM155L85
Voltage: 380V AC
Rated Electricity: 5KW
Optimum Energy:9KW(30s)
Fee Torque : 19N.m
Maximum Torque:34N.m
Rated Speed: 2500rpm
Optimum Pace:4000rpm
Rated Current:10A
Isolation: H
H2o/Dust Proof: IP54(IP67 option)
N Weight: around 15KG
Cooling Strategy: all-natural cooling
Installation Method: MB35

Application
High-velocity Compressors,Followers,Pumps

Other motors you will be fascinated in

Motor type Voltage
(V AC)
Rated electricity
(kW)
Rated torque (N.m) Rated speed
(rpm)
Performance
(%)
Provider Factor Insulation Ingress defense Pole Amount Fat
(kg)
Cooling Strategy Place Sign Set up Strategy
SRPM151M8XW11 380 eleven 11 9600 96 S1 H/F IP67 eight 10 Oil circulation Resolver B35
SRPM205M8XO45 380 forty five 36 12000 ninety six.3 S1 H/F IP67 8 35 Oil circulation Resolver B35
SRPM205M8XO55 380 fifty five 43.8 12000 ninety six.three S1 H/F IP67 eight 38 Oil circulation Resolver B35
SRPM205M8XO75 380 seventy five 59.7 12000 96.five S1 H/F IP67 8 43 Oil circulation Resolver B35
SRPM205M8XO90 380 90 71.six 12000 ninety six.five S1 H/F IP67 eight 47 Oil circulation Resolver B35
SRPM205M8XO110 380 a hundred and ten 87.6 12000 96.five S1 H/F IP67 eight 75 Oil circulation Resolver B35
SRPM205M8XO132 380 132 one hundred and five 12000 ninety six.5 S1 H/F IP67 eight 80 Oil circulation Resolver B35
SRPM205M8XO160 380 a hundred and sixty 127.3 12000 96.5 S1 H/F IP67 eight 87 Oil circulation Resolver B35
SRPM205M8XO185 380 185 147.2 12000 ninety six.five S1 H/F IP67 8 95 Oil circulation Resolver B35

FAQ
one. Can performanent magnet synchronous motor be utilised as generator? 

No. Long lasting magnet synchronous motor is totally different from generator. It is only ac motor that outputs speed and torque to travel electric powered units, but not electrical power provide. 
 
two. Why can not directly use a few period ac offer voltage to begin permanent magnet synchronous motor? 
Becuase rotor is with huge innertia, and magetic information spins so rapidly that static rotor has no way to spin with magetic filed. 
 
three. Any unique complex request on this motor's VFD driver? And Do you have such driver? 
Long lasting magnet synchronous motor's driver should be vector handle VFD with unique internal computer software, such as Siemens 6SE70 series, Yakawa CR5 collection, ABB ACS800 series, Mitsubishi A740 sequence, B&R P84 and P74 series, and many others.. Yes, our MH300 collection VFD matches with this motor. 
 
four. Is there any protective steps to defend everlasting magnet rotor from failure? 
Yes, each and every permanent magnet rotor passes corrossion resistance, regularity, high temperature demagnetization examination, linear demagnetization test, etc. Its demagnetization index is in 2%. But if functioning environment is significant oxiditive corrosion, kindly advise for greater protection amount. 
 
5. Where is this everlasting magnet synchronous motor generally utilised to? 
This permanent magnet synchronous motor is normally utilized to variable frequency velocity circumstance.

 